FINNED TUBE HEAT EXCHANGER

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To determine Heat transfer rate of heating & cooling.
2. To Calculate L.M.T.D.
3. To determine Overall Heat Transfer Coefficient Based on Internal &External Area of Tube.
4. To calculate Effectiveness of heat exchanger.
5. The experiments can be conducted at various values of input &calculation can be made accordingly.
TECHNICAL DESCRIPTION :
The apparatus consists of a tube in tube type concentric tube heat exchanger.
The hot fluid is hot water which is obtained from an electrical geyser & it flows through the inner tube. The Inner Tube Is provided with circular fins throughout the Length. While the cold fluid is cold water, flowing through annulas.The flow rate of hot and cold water are measured by using rotameter. Temperatures at inlet and outlet are measured by using thermocouples and temperature indicator.

DIMENSIONS AND WEIGHT :
Size :1.2 m.(L)x 0.7m(W) X 1.5 m ( H )
Weight :Approx. 70 Kg , Water: @10 Lpm
SERVICE REQUIRED :
230 v Ac Supply 50 Hz
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual
OPTIONAL FACILITY: Data logging Facility

Get More Details:- 21- FINNED TUBE HEAT EXCHANGER

SHELL AND TUBE HEAT EXCHANGER

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To determine Heat transfer rate of heating & cooling.
2. To Calculate L.M.T.D.
3. To determine Overall Heat Transfer Coefficient
4. To calculate Effectiveness of heat exchanger.
5. The experiments can be conducted at various values of input &calculation can be made accordingly.
TECHNICAL DESCRIPTION :
The apparatus consists of a Shell andTube type heat exchanger.
The hot fluid is hot water which is obtained from an electrical geyser & it flows through the inner tube. While the cold fluid is cold water, flowing through the shell.The flow rate of hot and cold water are measured by using rotameter. Temperatures at inlet and outlet are measured by using thermocouples and temperature indicator.
DIMENSIONS AND WEIGHT :
Size :1.2 m.(L)x 0.7m(W) X 1.5 m ( H )
Weight :Approx. 90 Kg , Water: @10 Lpm
SERVICE REQUIRED : 230 v Ac Supply 50 Hz
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual
OPTIONAL FACILITY: Data logging Facility

Get More Details:- 22- SHELL AND TUBE HEAT EXCHANGER

PARALLEL AND COUNTER FLOW HEAT EXCHANGER

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To determine Heat transfer rate of heating & cooling.
2. To Calculate L.M.T.D.
3. To determine Overall Heat Transfer Coefficient
4. To calculate Effectiveness of heat exchanger.
5. The experiments can be conducted at various values of input &calculation can be made accordingly.
TECHNICAL DESCRIPTION :
The apparatus consists of a tube in tube type concentric tube heat exchanger.
The hot fluid is hot water which is obtained from an electrical geyser & it flows through the inner tube. While the cold fluid is cold water, flowing through annulas. The hot water flows in one direction & the flow rate of which is collected by means of a valve. The cold water can be admitted at one end enabling the heat exchanger to run as a parallel flow apparatus or a counter flow apparatus this is done by wall operations. The flow rate of hot and cold water are measured by using rotameter. Temperatures at inlet and outlet are measured by using thermocouples and temperature indicator.

DIMENSIONS AND WEIGHT :
Size :1.2 m.(L)x 0.7m(W) X 1.5 m ( H )
Weight :Approx. 80 Kg , Water: @10 Lpm
SERVICE REQUIRED :
230 v Ac Supply 50 Hz
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual
OPTIONAL FACILITY: Data logging Facility

Get More Details:- 23- PARALLEL AND COUNTER FLOW HEAT EXCHANGER

REGENERATIVE HEAT EXCHANGER

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To determine Heat transfer rate of heating & cooling.
2. To Observe & calculate energy balance.
3. To calculate Effectiveness of heat exchanger.
4. The experiments can be conducted at various values
of input & calculation can be made accordingly
TECHNICAL DESCRIPTION :
The apparatus consists of a tube in tube type concentric tube heat exchanger.
The hot fluid is hot water which is obtained from an electrical geyser & it flows through the inner tube. While the cold fluid is cold water, flowing through the regenerative medium which is filled in annular space between tubes… The flow rate of hot and cold water are measured by using rotameter. Temperatures at inlet and outlet are measured by using thermocouples and temperature indicator.

DIMENSIONS AND WEIGHT :
Size :1.2 m.(L)x 0.7m(W) X 1.5 m ( H )
Weight :Approx. 90 Kg , Water: @10 Lpm
SERVICE REQUIRED :
230 v Ac Supply 50 Hz
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual
OPTIONAL FACILITY: Data logging Facility

Get More Details:- 24- REGENERATIVE HEAT EXCHANGER

PLATE TYPE HEAT EXCHANGER

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To determine Heat transfer rate of heating & cooling.
2. To Observe & calculate energy balance.
3. To calculate Effectiveness of heat exchanger.
4. The experiments can be conducted at various values
of input & calculation can be made accordingly
TECHNICAL DESCRIPTION :
The apparatus consists of plate type heat exchanger.
The hot fluid is hot water which is obtained from an electrical geyser & it flows through the plates. While the cold fluid is cold water, flowing through the annular space between plates. The flow rate of hot and cold water are measured by using rotameter. Temperatures at inlet and outlet are measured by using thermocouples and temperature indicator.
DIMENSIONS AND WEIGHT :
Size :1.2 m.(L)x 0.7m(W) X 1.5 m ( H )
Weight :Approx. 110 Kg , Water: @10 Lpm
SERVICE REQUIRED : 230 v Ac Supply 50 Hz
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual
OPTIONAL FACILITY: Data logging Facility

Get More Details:- 25- PLATE TYPE HEAT EXCHANGER

VERTICAL CONDENSER TEST RIG

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To determine Heat transferrate of heating & cooling.
2. To determine the overall andindividual film heat transfer
coefficients for a condensationof a vapour on a vertical Condenser.
3. To calculate Effectiveness of the Condenser.
4. The experiments can be conductedat various values of input &
calculation can be made accordingly.
TECHNICAL DESCRIPTION :
The double pipe ( 50 mm Dia x 100 mm Dia) having the test-section length of 1 m is provided with 1 meter inlet and outlet calming section for the inner pipe. Steam ( or any condensable organic vapour ) is admitted in the jacket. The pressure and temperature of the vapour is indicated by pressure gauge and Temperature Indicator . Condensate rate could be measured by collecting it in to a receiver in known time. The flow rate of cold water flowing through the inner pipe is known by rotameter.

DIMENSIONS AND WEIGHT :
Size :1.2 m.(L)x 1 m(W) X 2m ( H )
Weight :Approx. 110 Kg , Water: @10 Lpm
SERVICE REQUIRED :
440 v Ac Supply 50 Hz, Three Phase.
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual
OPTIONAL FACILITY: Data logging Facility

Get More Details:- 26- VERTICAL CONDENSER

CROSS FLOW HEAT EXCHANGER

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To determine Heat transfer rate of heating & cooling.
2. To determine Overall heat transfer coefficient.
3. To calculate Effectiveness of heat exchanger.
4. The experiments can be conducted at various values of
input & calculation can be made accordingly.
TECHNICAL DESCRIPTION :
The apparatus consists of a Shell and Tube type Cross flow heat exchanger.
The hot fluid is hot water which is obtained from an electrical geyser & it flows through the inner tube. While the cold fluid is cold water, flowing through the shell. The flow rate of hot and cold water are measured by using rotameter. Temperatures at inlet and outlet are measured by using thermocouples and temperature indicator.
DIMENSIONS AND WEIGHT :
Size :1.2 m.(L)x 1 m(W) X 2m ( H )
Weight :Approx. 110 Kg , Water: @10 Lpm
SERVICE REQUIRED :
440 v Ac Supply 50 Hz, Three Phase.
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual
3.
OPTIONAL FACILITY: Data logging Facility

Get More Details:- 27- CROSS FLOW HEAT EXCHANGER

COILED TUBE HEAT EXCHANGER

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To determine Heat transfer rate of heating & cooling.
2. To determine Overall heat transfer coefficient.
3. To calculate Effectiveness of heat exchanger.
4. The experiments can be conducted at various values of
input & calculation can be made accordingly.
TECHNICAL DESCRIPTION :
The apparatus consists of a Shell and Tube type coiled tube heat exchanger.
The hot fluid is hot water which is obtained from an electrical geyser & it flows through the coiled tube. While the cold fluid is cold water, flowing through the shell. The flow rate of hot and cold water are measured by using rotameter. Temperatures at inlet and outlet are measured by using thermocouples and temperature indicator.
DIMENSIONS AND WEIGHT :
Size :1.2 m.(L)x 1 m(W) X 2m ( H )
Weight :Approx. 90 Kg , Water: @10 Lpm
SERVICE REQUIRED :
440 v Ac Supply 50 Hz, Three Phase.
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual
OPTIONAL FACILITY: Data logging Facility

Get More Details:- 28- COILED TUBE HEAT EXCHANGER

SPIRAL TUBE HEAT EXCHANGER

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To determine Heat transfer rate of heating & cooling.
2. To determine Overall heat transfer coefficient.
3. To calculate Effectiveness of heat exchanger.
4. The experiments can be conducted at various values of
input & calculation can be made accordingly.
TECHNICAL DESCRIPTION :
The apparatus consists of a Shell and Tube type spiral tube heat exchanger.
The hot fluid is hot water which is obtained from an electrical geyser & it flows through the coiled tube. While the cold fluid is cold water, flowing through the shell. The flow rate of hot and cold water are measured by using rotameter. Temperatures at inlet and outlet are measured by using thermocouples and temperature indicator.
DIMENSIONS AND WEIGHT :
Size :1.2 m.(L)x 1 m(W) X 2m ( H )
Weight :Approx. 90 Kg , Water: @10 Lpm
SERVICE REQUIRED : 440 v Ac Supply 50 Hz, Three Phase.
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual
OPTIONAL FACILITY: Data logging Facility

Get More Details:- 29- SPIRAL TUBE HEAT EXCHANGER

HORIZONTAL CONDENSER TEST RIG

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To determine Heat transferrate of heating & cooling.
2. To determine the overall andindividual film heat transfer
coefficients for a condensationof a vapour on a Horizontal Condenser.
3. To calculate Effectiveness of the Condenser.
4. The experiments can be conductedat various values of input &
calculation can be made accordingly.
TECHNICAL DESCRIPTION :
The shell and tube type horizontal condenser. Steam ( or any condensable organic vapour ) is admitted in the Shell Side. The pressure and temperature of the vapour is indicated by pressure gauge and Temperature Indicator . Condensate rate could be measured by collecting it in to a receiver in known time. The flow rate of cold water flowing through the inner pipe is known by rotameter.
DIMENSIONS AND WEIGHT :
Size :1.2 m.(L)x 1 m(W) X 2m ( H )
Weight :Approx. 110 Kg , Water: @10 Lpm
SERVICE REQUIRED : 440 v Ac Supply 50 Hz, Three Phase.
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual
OPTIONAL FACILITY: Data logging Facility

Get More Details:-