ABSORPTION IN BUBBLE COLUMN

DESCRIPTION : The Absorption column should consist of Glass column . The device must equipped with a gas inlet and distributing space at the bottom, a liquid inlet and distributor at the top, gas and liquid outlet at top and bottom respectively. The gas and air are metered separately, mixed and then passed through the bed vertically upwards and absorbed in liquid . All the flow rates can be independently varied to simulate different conditions.
RANGE OF EXPERIMENTS :
1. To study the characteristics of absorption with chemical reaction.
2. To calculate the rate of absorption.
3. To calculate the interfacial area per unit volume

EXPERIMENTAL SETUP :
Column : Borosilicate Glass Column
Flow Measurement : 3 No. Pre calibrated Rota meter
Feed Tank : 1 No. of stainless steel feed tank
Product receiver : 1 No. SS tank
Gas supply : 1 No. of gas cylinder with Pressure Gauge
Piping : SS , PVC
Setup Mounting : On sturdy MS stand with
powder coated
SPACE REQUIRED : 1.5 m. ( L) x 1.0 m (W) X 2.5 m (H).
SERVICE REQUIRED: Air Supply : @ 6 CFM, at 4 Kg /cm2
CHEMICALS REQUIRED: NaOH, HCL, Phenolphthalein indicator ,
Distilled water
WEIGHT : @ 55 Kg

Get More Details:- 01-ABSORPTION IN BUBBLE COLUMN

ABSORPTION IN BUBBLE CAP COLUMN

DESCRIPTION : The Absorption column consist of Stainless steel column . The device is equipped with a gas inlet and distributing space at the bottom, a liquid inlet and distributor at the top, gas and liquid outlet at top and bottom respectively. The gas and air are metered separately, mixed and then passed through the bed vertically upwards and absorbed in liquid . All the flow rates can be independently varied to simulate different conditions.
RANGE OF EXPERIMENTS TO BE CARRIED OUT :
1. To study the Characteristics of absorption with chemical reaction
2. To calculate the rate of absorption per unit volume
3. To calculate the interfacial area per unit volume
EXPERIMENTAL SETUP :
Column : Stainless Steel Column
Packing : Bubble Caps
Flow Measurement : 3 No. Pre calibrated Rota meter
Feed Tank : 1 No. of stainless steel feed tank
Product receiver : 1 No. SS tank
Gas supply : 1 No. of gas cylinder with Pressure
Gauge
Piping : SS , PVC
Setup Mounting : On sturdy MS stand with powder
coated
SPACE REQUIRED : 1.5 m. ( L) x 1.0 m (W) X 2.5 m (H).
SERVICE REQUIRED: Air Supply : @ 6 CFM, at 4 Kg /cm2
CHEMICALS REQUIRED: NaOH, HCL, Phenolphthalein indicator ,
Distilled water
WEIGHT : @ 55 Kg

Get More Details:- 02-ABSORPTION IN BUBBLE CAP COLUMN

ABSORPTION IN TRAY COLUMN

DESCRIPTION : The Absorption column consist of Stainless steel column .The device is equipped with a gas inlet and distributing space at the bottom, a liquid inlet and distributor at the top, gas and liquid outlet at top and bottom respectively. The gas and air are metered separately, mixed and then passed through the bed vertically upwards and absorbed in liquid . All the flow rates can be ndependently varied to simulate different conditions. RANGE OF EXPERIMENTS TO BE CARRIED OUT : 1. To study the Characteristics of absorption with chemical reaction 2. To calculate the rate of absorption per unit volume 3. To calculate the interfacial area per unit volume\ EXPERIMENTAL SETUP Column : Stainless Steel Column Packing : Trays Flow Measurement : 3 No. Pre calibrated Rota meter Feed Tank : 1 No. of stainless steel feed tank Product receiver : 1 No. SS tank Gas supply : 1 No. of gas cylinder with Pressure Gauge Piping : SS , PVC Setup Mounting : On sturdy MS stand with powder coated

SPACE REQUIRED : 1.5 m. ( L) x 1.0 m (W) X 2.5 m (H).
SERVICE REQUIRED: Air Supply : @ 6 CFM, at 4 Kg /cm2
CHEMICALS REQUIRED: NaOH, HCL, Phenolphthalein indicator ,
Distilled water
WEIGHT : @ 55 Kg

Get More Details:- 03-ABSORPTION IN TRAY COLUMN

ABSORPTION IN PACKED COLUMN

DESCRIPTION : The Absorption column is consist of glass column packed with Rasching rings. The device is equipped with a gas inlet and distributing space at the bottom, a liquid inlet and distributor at the top, gas and liquid outlet at top and bottom respectively. The gas and air are metered separately, and then passed through the bed vertically upwards and absorbed in liquid . All the flow rates can be independently varied to simulate different conditions.
RANGE OF EXPERIMENTS TO BE CARRIED OUT :
1. To study the Characteristics of absorption with chemical reaction
2. To calculate the rate of absorption per unit volume
3. To calculate the interfacial area per unit volume
EXPERIMENTAL SETUP :
Column : Borosilicate Glass Column
Packing : Raschig Ring
Flow Measurement : 3 No. Pre calibrated Rota meter
Feed Tank : 1 No. of stainless steel feed tank
Product receiver : 1 No. SS tank
Gas supply : 1 No. of gas cylinder with Pressure
Gauge
Piping : SS , PVC
Setup Mounting : On sturdy MS stand with powder
Coated

SPACE REQUIRED : 1.5 m. ( L) x 1.0 m (W) X 2.5 m (H).
SERVICE REQUIRED: Air Supply : @ 6 CFM, at 4 Kg /cm2
CHEMICALS REQUIRED: NaOH, HCL, Phenolphthalein indicator ,
Distilled water
WEIGHT : @ 55 Kg

Get More Details:- 04-ABSORPTION IN PACKED COLUMN

ABSORPTION IN WETTED WALL COLUMN

DESCRIPTION : The Absorption column consist of Glass column . The device is equipped with a gas inlet and distributing space at the bottom, a liquid inlet and distributor at the top, gas and liquid outlet at top and bottom respectively. The gas and air are metered separately, mixed and then passed through the bed vertically upwards and absorbed in liquid . All the flow rates can be independently varied to simulate different conditions.
RANGE OF EXPERIMENTS TO BE CARRIED OUT :
1. To study the Characteristics of absorption with chemical reaction
2. To calculate the rate of absorption per unit volume
3. To calculate the interfacial area per unit volume
EXPERIMENTAL SETUP :
Column : Borosilicate Glass Column
Flow Measurement : 3 No. Pre calibrated Rota meter
Feed Tank : 1 No. of stainless steel feed tank
Product receiver : 1 No. SS tank
Gas supply : 1 No. of gas cylinder with
Pressure Gauge
Piping : SS , PVC
Setup Mounting : On sturdy MS stand with
powder coated

SPACE REQUIRED : 1.5 m. ( L) x 1.0 m (W) X 2.5 m (H).
SERVICE REQUIRED: Air Supply : @ 6 CFM, at 4 Kg /cm2
CHEMICALS REQUIRED: NaOH, HCL, Phenolphthalein indicator ,
Distilled water
WEIGHT : @ 55 Kg

Get More Details:- 05-ABSORPTION IN WETTED WALL COLUMN

ADSORPTION IN PACKED COLUMN

DESCRIPTION : The Adsorption column consist of glass column filled with adsorbent. The feed is introduced from the top of the column . The solute from the feed solution is adsorbed on the adsorbent surface. After the operation the solution drain out and analysed.Steam
RANGE OF EXPERIMENTS TO BE CARRIED OUT :
1. To study the Characteristics of adsorption with chemical reaction
2. To calculate the amount of adsorption of solute on adsorbate
3. To calculate the separation factor
4. To plot the Freundlich adsorption isotherm.
EXPERIMENTAL SETUP :
Column : Borosilicate Glass Column
Packing : Adsorbate on Teflon ring
Flow Measurement : 1 No. Pre calibrated Rota meter
Feed Tank : 1 No. of stainless steel feed tank
Product receiver : 1 No. SS tank
Feed Circulation : By Compressed Air
Pressure Regulator : 0 – 2 kgf / cm2
Pressure Gauge : Bourdon type0 – 2 kgf / cm2
Steam Generator : Electrically heated Baby boiler with
Pressure Gauge
Piping : SS , PVC

Get More Details:- 06-PACKED COLUMN ADSORPTION

MASS TRANSFER WITH CHEMICAL REACTION

DESCRIPTION: In this reactor contents are well stirred with the catalyst and uniform throughout. Thus exit stream from this reactor has the same composition as the fluid within the reactor. We can refer also mixed type reactor
RANGE OF EXPERIMENTS TO BE CARRIED OUT :
1. To study mass transfer with chemical
2. To calculate the rate constant k of given reaction
EXPERIMENTAL SETUP
Reactor : Material Stainless steel (SS) ,
Flow Measurement : 1 No. Pre calibrated Rota meter
Feed Tank : 2 No. of stainless steel feed tank
Feed Circulation : By Compressed Air
Pressure Regulator : 0 – 2 kgf / cm2
Pressure Gauge : Bourdon type0 – 2 kgf / cm2
Water Bath : Material SS , Double Wall ,
\ Insulated with glass Wool
Heater : Nichrome wire heater
Stirrer : 1 No.SS impeller and shaft coupled to
FHP Motor
Digital Temp Indicator : 0 – 200 0 C , Indicator cum Controller
Temp Sensor : CR/AL Type
Piping : SS, PVC
Setup Mounting : On sturdy MS stand with powder coated.

Get More Details:- 07-MASS TRANSFER WITH CHEMICAL REACTION

WETTED WALL COLUMN

DESCRIPTION: A Thin film of liquid running down the inside of vertical pipe, with gas flowing either concurrently or counter currently, constitutes a wetted wall tower. In this the liquid is dispersed into thin film .Measurement of the rate of evaporation of the liquid in to the gas stream over known surface permits calculation of the mass transfer coefficients for the gas phase
RANGE OF EXPERIMENTS TO BE CARRIED OUT :
1. To study the Wetted wall column
2. To calculate the Gas phase mass transfer coefficient
EXPERIMENTAL SETUP :
Column : Borosilicate Glass Column
Flow Measurement : 2 No. Pre calibrated Rota meter
Feed Tank : 1 No. of stainless steel feed tank
Heater : Nichrome wire heater
Digital Temp Indicator : 0 – 200 0 C ,
Temp Sensor : CR/AL Type
Pump : FHP Submersible pump
Piping : SS , PVC
Setup Mounting : On sturdy MS stand with
powder coated
SPACE REQUIRED : 1.5 m. ( L) x 1.0 m (W) X 2.5 m (H).
SERVICE REQUIRED: Air Supply : @ 6 CFM, at 4 Kg /cm2
Power Supply : 230V, 50Hz, A. C.
WEIGHT : @ 55 Kg

Get More Details:- 08-WETTED WALL COLUMN

SIMPLE DISTILLATION SETUP

DESCRIPTION: The equipment consists of Borosilicate glass round bottom flask as distillation still . The distillation is carried out by heating the still. The vapors coming from the column is going in to the condenser. The distillate is collected in round bottom flask RANGE OF EXPERIMENTS TO BE CARRIED OUT : 1. To study the simple distillation 2. To verify Rayleigh Equation for simple distillation EXPERIMENTAL SETUP: Reboiler : Borosilicate glass round bottom flask Distillate Receiver : Borosilicate glass round bottom flask Condenser : Borosilicate glass double pipe condenser Heating Mantle : Aluminum body with fiber cloth and with Thermostat Digital Temp Indicator : 0 – 400 0 C , Temp Sensor : Mercury Thermometer Piping : PVC Setup Mounting : On sturdy MS stand with powder coated SPACE REQUIRED : 1.5 m. ( L) x 1.0 m (W) X 0.6 m (H). SERVICE REQUIRED: Water Supply : @2 LPM Power Supply : 230V, 50Hz, A. C. Specific Gravity Bottle. CHEMICALS REQUIRED : Methanol, Ethanol. WEIGHT : @ 55 Kg

Get More Details:- 09-SIMPLE DISTILLATION SETUP

STEAM DISTILLATION SETUP

DESCRIPTION: The equipment consists of Borosilicate glass round bottom flask as distillation still. The distillation is carried out by using steam. The vapors coming from the column is going in to the condenser. The distillate is collected in round bottom flask. RANGE OF EXPERIMENTS TO BE CARRIED OUT : 1. To study the simple steam distillation 2. To calculate the steam required for the distillation EXPERIMENTAL SETUP : Reboiler : Borosilicate glass round bottom flask Distillate Receiver : Borosilicate glass round bottom flask Condenser : Borosilicate glass double pipe condenser Steam Generator : Electrically heated baby boiler with Pressure gauge, Safety Valve Digital Temp Indicator : 0 – 400 0 C , Temp Sensor : CR/AL Type Pump : FHP Submersible pump Piping : PVC Setup Mounting : On sturdy MS stand with powder coated SPACE REQUIRED : 1.5 m. ( L) x 1.0 m (W) X 0.7 m (H). SERVICE REQUIRED : Power Supply: 230 V, 50 Hz, A.C. CHEMICALS REQUIRED : Turpentine. WEIGHT : @ 55 Kg

Get More Details:- 10-STEAM DISTILLATION SETUP