VERTICAL CONDENSER TEST RIG

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To determine Heat transferrate of heating & cooling.
2. To determine the overall andindividual film heat transfer
coefficients for a condensationof a vapour on a vertical Condenser.
3. To calculate Effectiveness of the Condenser.
4. The experiments can be conductedat various values of input &
calculation can be made accordingly.
TECHNICAL DESCRIPTION :
The double pipe ( 50 mm Dia x 100 mm Dia) having the test-section length of 1 m is provided with 1 meter inlet and outlet calming section for the inner pipe. Steam ( or any condensable organic vapour ) is admitted in the jacket. The pressure and temperature of the vapour is indicated by pressure gauge and Temperature Indicator . Condensate rate could be measured by collecting it in to a receiver in known time. The flow rate of cold water flowing through the inner pipe is known by rotameter.

DIMENSIONS AND WEIGHT :
Size :1.2 m.(L)x 1 m(W) X 2m ( H )
Weight :Approx. 110 Kg , Water: @10 Lpm
SERVICE REQUIRED :
440 v Ac Supply 50 Hz, Three Phase.
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual
OPTIONAL FACILITY: Data logging Facility

Get More Details:- 26- VERTICAL CONDENSER