CALIBRATION OF VENTURIMETER AND ORIFICEMETER ROTAMETER APPARATUS

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To Calculate the venturimeter coefficient of given venture meter and compare with the reported value in literature.
2. To predict the flow rate by using average value of coefficient of venturimeter
3. To Calculate the Orificemeter coefficient of given Orificemeter and compare with the reported value in literature.
4. To predict the flow rate by using average value of coefficient of Orificemeter
5. To predict the flow rate by using Rotameter
TECHNICAL DESCRIPTION :
The experimental unit consist of venturimeter and Orifice meter ,Rotameter fixed in the pipe. a water sump tank with self-priming monoblock centrifugal pump. The flow of water can be controlled by a valve.. A measuring tank is provided for measurement of discharge of water through the Section. The Differential Pressure across the venturimeter and Orifice meter is measured by using U tube Manometer.This system is complete closed circuit type and easy to move due to wheels.This system is complete closed circuit type and easy to move due to wheels.

DIMENSIONS AND WEIGHT :
Size :1.5 m.(L)x 0.7 m(W) X 1.2m ( H )
Weight :Approx. 40 Kg
SERVICE REQUIRED :
Power Supply : 230v, AC ,Single Phase , 50HZ
Water :80 ltr
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual

Get More Details:- 1-CALIBRATION OF VENTURIMETER ORIFICE ROTAMETER APPARATUS

MEASUREMENT OF LEVEL BY AIR PURGE METHOD

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To measure the level by using air purge method.
TECHNICAL DESCRIPTION :
The setup consist of a water tank with window glass fitted in MS casing. A copper tubing is provided at bottom of tank. An air purging valve provided with copper tubing. An acrylic body manometer provided with the setup. The whole unit is mounted on sturdy setup , powder coated with good color combination.
DIMENSIONS AND WEIGHT :
Size :1 m.(L)x 0.7 m(W) X 1.2m ( H )
Weight :Approx. 20 Kg
SERVICE REQUIRED :
Air Supply : @2 kg/cm2
Water :20 ltr
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual

Get More Details:- 2-MEASUREMENT OF LEVEL BY AIR PURGE METHOD

TIME CONSTANT OF THERMOMETER

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To Determine the time const of given thermometer
TECHNICAL DESCRIPTION :
Here two Different types of Thermometers are selected & used to measure the temperature.. The output signal from signal conditioning card is fed to next Microcontroller based Digital readout & its related circuit will be selected & actual measured temperature will be shown on Digital Read Out. An electric kettle is also provided for water bath.and also mercury glass thermometer.
DIMENSIONS AND WEIGHT :
Size :0.3 m.(L)x 0.3m(W) X 0.3m ( H )
Weight :Approx. 2 Kg
SERVICE REQUIRED :
POWER SUPPLY :
230V AC Single Phase

Get More Details:- 3-TIME CONSTANT OF THERMOMETER

TIME CONSTANT OF MANOMETER

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To Determine the time constant of given Manometer
TECHNICAL DESCRIPTION :
Here Three Different lengths of manometer are selected & used to measure the manometer difference. An air filter regulator is used to provide air at constant pressure.
DIMENSIONS AND WEIGHT :
Size :0.7 m.(L)x 0.5m(W) X 1.2m ( H )
Weight :Approx. 20 Kg
SERVICE REQUIRED :
Air Supply : @2 kg/cm2

Get More Details:- 4-TIME CONSTANT OF MANOMETER

THERMOCOUPLE CALIBRATION SETUP

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To study the Temperature Measurement Thermocouple.
TECHNICAL DESCRIPTION :
Here three Different types of Thermocouples are selected & used to measure the temperature.. The output signal from signal conditioning card is fed to next Microcontroller based Digital readout & its related circuit will be selected & actual measured temperature will be shown on Digital Read Out. An electric kettle is also provided for water bath.and also mercury glass thermometer.
DIMENSIONS AND WEIGHT :
Size :0.3 m.(L)x 0.3m(W) X 0.3m ( H )
Weight :Approx. 2 Kg
SERVICE REQUIRED :
POWER SUPPLY :
230V AC Single Phase
Water : 1 ltr
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual

Get More Details:- 5-THERMOCOUPLE CALIBRATION SETUP (1)

BIMETALLIC CALIBRATION SETUP

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To study the Temperature Measurement using Bimetallic Sensor
TECHNICAL DESCRIPTION :
Here Bimetallic Sensor is used to measure the temperature.. The output signal from signal conditioning card is fed to next Microcontroller based Digital readout & its related circuit will be selected & actual measured temperature will be shown on Digital Read Out. An electric kettle is also provided for water bath.and also mercury glass thermometer.
DIMENSIONS AND WEIGHT :
Size :0.3 m.(L)x 0.3m(W) X 0.3m ( H )
Weight :Approx. 2 Kg
SERVICE REQUIRED :
POWER SUPPLY :
230V AC Single Phase
Water : 1 ltr
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual

Get More Details:- 6-BIMETALLIC CALIBRATION SETUP

THERMISTER CALIBRATION SETUP

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To study the Temperature Measurement using Thermister
TECHNICAL DESCRIPTION :
Here Thermister sensor is used to measure the temperature.. The output signal from signal conditioning card is fed to next Microcontroller based Digital readout & its related circuit will be selected & actual measured temperature will be shown on Digital Read Out. An electric kettle is also provided for water bath.and also mercury glass thermometer.
DIMENSIONS AND WEIGHT :
Size :0.3 m.(L)x 0.3m(W) X 0.3m ( H )
Weight :Approx. 2 Kg
SERVICE REQUIRED :
POWER SUPPLY : 230V AC Single Phase, Water : 1 ltr
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual

Get More Details:- 7-THERMISTER CALIBRATION SETUP

DEAD WEIGHT PRESSURE GAUGE TESTER

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1.To determine unknown sample weight using given pressure gauge
2. To calibrate the given pressure gauge
TECHNICAL DESCRIPTION :
Pressure Gauge is the simplest apparatus used for measuring pressure inside closed system. There are three main components of this device: fluid oil that transmits pressure ,dead weights and piston that applies pressure and pressure gauge which measure the pressure. It also contains oil reservoir which accumulate oil displaced by piston during tests.The whole setup is mounted on sturdy MS plate with good colour combination.
DIMENSIONS AND WEIGHT :
Size :0.5 m.(L)x 0.5m(W) X 0.4m ( H )
Weight :Approx. 3 Kg
SERVICE REQUIRED :
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual

Get More Details:- 08-DEAD WEIGHT PRESSURE GAUGE TESTER

DEAD WEIGHT VACUUM GAUGE TESTER

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To calibrate the given Vacuum gauge
TECHNICAL DESCRIPTION :
The setup consist of screw pump to generate the vacuum. The free piston assembly is connected to the screw pump. The set of dead weights is attached to the piston assembly. The whole setup is mounted on sturdy MS plate with good color combination.
DIMENSIONS AND WEIGHT :
Size :0.5 m.(L)x 0.5m(W) X 0.4m ( H )
Weight :Approx. 3 Kg
SERVICE REQUIRED :
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual

Get More Details:- 09-DEAD WEIGHT VACCUM GAUGE TESTER

PERFORMANCE OF PNEUMATIC PI CONTROLLER

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To Study the pneumatic PI Controller.
TECHNICAL DESCRIPTION :
The setup consist of pneumatic PI controller. An air filter regulator is used to provide constant air supply. A pneumatic actuated diaphragm control valve is act as final control element. The whole setup mounted on sturdy iron frame , powder coated with good color combination.
DIMENSIONS AND WEIGHT :
Size :0.75 m.(L)x 0.5m(W) X 1.2m ( H )
Weight :Approx. 75 Kg
SERVICE REQUIRED :
Air Supply : @ 5 kg/cm2
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual

Get More Details:- 10-PERFORMANCE OF PNEUMATIC PI CONTROLLER