CUT SECTION MODEL OF ROTARY COMPRESSOR

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To study all components used in Compressor
TECHNICAL DESCRIPTION :
The model is made out of original used part. The painting is carried out in such way that different color is used for different component such as identification of sectioned area ,different mechanisms etc . The model is mounted on sturdy frame
DIMENSIONS AND WEIGHT :
Size :0.3 m.(L)x 0.3 m(W) X 0.5m ( H )
Weight :Approx. 10 Kg
SCOPE OF DELIVERY:
1. Cut section model

Get More Details:- 23- MODEL OF ROTARY COMPRESSOR

COMPUTERISED AIR CONDITIONING CYCLE TEST RIG

TECHNICAL DESCRIPTION :
The equipment consists of a hermetically sealed compressor, air cooled condenser, blower unit to force air through a duct mounted on frame, an evaporator adopted in the duct, heaters of suitable capacity are clamped in the duct.
The power to the heater can be controlled & the air is warmed while it passes over the heater. The mass flow rate of air in the duct can be varied by arrangement provided on the blower unit. There is arrangement provided on the blower unit. There is an arrangement for humidification achieved by introducing fog in the duct. The relative humidity of air at inlet & outlet can be measured by a humidity sensor. An expansion valve is provided in the circuit for throttling the gas from HP to LP. There are two gauges for measurement of high & low pressure. Four thermocouples are placed to measure the temperature of gas at the evaporator & condenser, with help of digital temperature indicator. HP/LP cut out is provided for the safety of compressor. The duct is insulated from out side to avoid the heat loss.
The control panel consists of Main switch, Compressor switch, switch for solenoid or capillary , Swich for heater , switch for for, voltmeter, ammeter , Pressure Indicator , Temperature Indicator, Power Indicator, Velocity Indicator , Humidity Indicator.etc. and Output for RS.232.
The refrigeration circuit & duct are mounted on a fabricated frame.

DIMENSIONS AND WEIGHT :
Size :3 m.(L)x 1.5 m(W) X 1.5m ( H )
Weight :Approx. 160 Kg
SERVICE REQUIRED :
230 v Ac Supply 50 Hz
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual
3. Data logging Facility

Get More Details:- 67-COMPUTERISED AIR CONDITIONING CYCLE TEST RIG

ICE PLANT TEST RIG

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To study all components used in refrigeration system.
2. To study the Vapor compression Refrigeration cycle.
3. To study the concept of Ice formation.
4. To determine the Refrigeration Effect, Work Input, Actual C.O.P.,Carnot C.O.P., Theoretical C.O.P., Relative
C.O.P., Ton of Refrigeration, and Plant Efficiency.
TECHNICAL DESCRIPTION :
The present equipment uses compression cycle system with Freon – 134a as the cooling media. The unit differs in many aspects than the commercial plants.
The equipments consists of control panel, condensing unit, cooling system, brine solution tank & a main tank etc. The brine tank is insulated from all sides with a door at the top side to load/unload the cans. The brine is placed in main tank.
The brine tank has a structure at the top side where the cans be hold. An agitator ( stirrer ) is used to stir the brine solution. A drain is provided to the brine tank. This tank is coated from inside to prevent any action by brine.
The compressor is mounted at one side of base with a condenser & fan. A liquid receiver is adopted in the circuit. The evaporator coil is held at one side in the brine tank..

The panel consists of switches, energymeter, pressure gauges, HP/LP cutout,
Thermostat
DIMENSIONS AND WEIGHT :
Size :2.5 m.(L)x 1.5 m(W) X 1.5m ( H )
Weight :Approx. 250 Kg
SERVICE REQUIRED :
230 v Ac Supply 50 Hz
Brine Solution : 70 ltr
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual
OPTIONAL FACILITY: Data logging Facility

Get More Details:- 1-ICE PLANT

COLD STORAGE PLANT

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To study all components used in refrigeration system.
2. To study the Vapor compression Refrigeration cycle.
3. To study the concept of Cold Storage.
4. To determine the Refrigeration Effect, Work Input, Actual C.O.P.,Carnot C.O.P., Theoretical C.O.P., Relative
C.O.P., Ton of Refrigeration, and Plant Efficiency.
TECHNICAL DESCRIPTION :
The equipment consist of Storage Room of 4 Ft x 4 Ft x 4 Ft with double wall insulated.Suitable small door for the cold storage.
uses compression cycle system with Freon – 134a as the cooling media. The unit differs in many aspects than the commercial plants.
The equipments consists of control panel, condensing unit, cooling system, storage room. The compressor is mounted at one side of base with a condenser & fan. A liquid receiver is adopted in the circuit. The evaporator coil is held at top of storage room.
The panel consists of switches, energymeter, pressure gauges, HP/LP cutout

DIMENSIONS AND WEIGHT :
Size :2.5 m.(L)x 2.5 m(W) X 2.5m ( H )
Weight :Approx. 2500 Kg
SERVICE REQUIRED :
440 v Ac Supply 50 Hz
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual
OPTIONAL FACILITY: Data logging Facility

Get More Details:- 2-COLD STORAGE PLANT

AIR CONDITIONING CYCLE TEST RIG

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To study all components used in Air Conditioning system.
2. To study the Vapor compression Refrigeration cycle.
3. To study the cooling, humidification,& dehumidification process.
4. To determine the Refrigeration Effect, Work Input, Actual C.O.P.,Carnot C.O.P., Theoretical C.O.P., Relative C.O.P., Ton ofRefrigeration, and Plant Efficiency.
TECHNICAL DESCRIPTION :
The equipment consists of a hermetically sealed compressor, air cooled condenser, blower unit to force air through a duct mounted on frame, an evaporator adopted in the duct, heaters of suitable capacity are clamped in the duct.
The power to the heater can be controlled & the air is warmed while it passes over the heater. Rotameter is used in the regeneration circuit which measures the flow of refrigerant (R-134a). The mass flow rate in the duct can be varied by arrangement provided on the blower unit. There is arrangement provided on the blower unit. There is an arrangement for humidification achieved by introducing steam in the duct. The relative humidity of air at inlet & outlet can be measured by a dry/wet bulb thermometer. An expansion valve is provided in the circuit for throttling the gas from HP to LP. There are two gauges for measurement of high & low pressure. Four thermocouples are placed to measure the temperature of gas at the evaporator & condenser, with help of digital temperature indicator.

HP/LP cut out is provided for the safety of compressor. The duct is insulated
from out side to avoid the heat loss.
The control panel consists of switches starter, voltmeter ammeter etc. The
measurement of power consumption of compressor by using energymeter.
The refrigeration circuit & duct are mounted on a fabricated frame. The blower
driven by motor is mounted on separate frame.
DIMENSIONS AND WEIGHT :
Size :3 m.(L)x 1.5 m(W) X 1.5m ( H )
Weight :Approx. 160 Kg
SERVICE REQUIRED :
440 v Ac Supply 50 Hz
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual
OPTIONAL FACILITY: Data logging Facility

Get More Details:- 4- AIR CONDITIONING CYCLE TEST RIG

AIR CONDITIONING CYCLE TEST RIG

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To study all components used in Air Conditioning system.
2. To study the Vapor compression Refrigeration cycle.
3. To study the cooling, humidification,& dehumidification process.
4. To determine the Refrigeration Effect, Work Input, Actual C.O.P.,Carnot C.O.P., Theoretical C.O.P., Relative C.O.P., Ton ofRefrigeration, and Plant Efficiency.
TECHNICAL DESCRIPTION :
The equipment consists of a hermetically sealed compressor, air cooled condenser, blower unit to force air through a duct mounted on frame, an evaporator adopted in the duct, heaters of suitable capacity are clamped in the duct.
The power to the heater can be controlled & the air is warmed while it passes over the heater. Rotameter is used in the regeneration circuit which measures the flow of refrigerant (R-134a). The mass flow rate in the duct can be varied by arrangement provided on the blower unit. There is arrangement provided on the blower unit. There is an arrangement for humidification achieved by introducing steam in the duct. The relative humidity of air at inlet & outlet can be measured by a dry/wet bulb thermometer. An expansion valve is provided in the circuit for throttling the gas from HP to LP. There are two gauges for measurement of high & low pressure. Four thermocouples are placed to measure the temperature of gas at the evaporator & condenser, with help of digital temperature indicator.

HP/LP cut out is provided for the safety of compressor. The duct is insulated
from out side to avoid the heat loss.
The control panel consists of switches starter, voltmeter ammeter etc. The
measurement of power consumption of compressor by using energymeter.
The refrigeration circuit & duct are mounted on a fabricated frame. The blower
driven by motor is mounted on separate frame.
DIMENSIONS AND WEIGHT :
Size :3 m.(L)x 1.5 m(W) X 1.5m ( H )
Weight :Approx. 160 Kg
SERVICE REQUIRED :
440 v Ac Supply 50 Hz
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual
OPTIONAL FACILITY: Data logging Facility

Get More Details:- 4- AIR CONDITIONING CYCLE TEST RIG

005 INDIRECT AIR CONDITIONING CYCLE TEST RIG

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To study all components used in Air Conditioning system.
2. To study the Vapor compression Refrigeration cycle.
3. To study the cooling, humidification,& dehumidification process.
4. To determine the Refrigeration Effect, Work Input, Actual C.O.P.,Carnot C.O.P., Theoretical C.O.P., Relative C.O.P., Ton ofRefrigeration, and Plant Efficiency.
TECHNICAL DESCRIPTION :
The equipment consists of a hermetically sealed compressor, air cooled condenser, blower unit to force air through a duct mounted on frame, an evaporator adopted in the duct, heaters of suitable capacity are clamped in the duct.
The power to the heater can be controlled & the air is warmed while it passes over the heater. Rotameter is used in the regeneration circuit which measures the flow of refrigerant (R-134a). The mass flow rate in the duct can be varied by arrangement provided on the blower unit. There is arrangement provided on the blower unit. There is an arrangement for humidification achieved by introducing steam in the duct. The relative humidity of air at inlet & outlet can be measured by a dry/wet bulb thermometer. An expansion valve is provided in the circuit for throttling the gas from HP to LP. There are two gauges for measurement of high & low pressure. Four thermocouples are placed to measure the temperature of gas at the evaporator & condenser, with help of digital temperature indicator.
HP/LP cut out is provided for the safety of compressor. The duct is insulated
from out side to avoid the heat loss.
The control panel consists of switches starter, voltmeter ammeter etc. The
measurement of power consumption of compressor by using energymeter.
The refrigeration circuit & duct are mounted on a fabricated frame. The blower
driven by motor is mounted on separate frame.
DIMENSIONS AND WEIGHT :
Size :3 m.(L)x 2.5 m(W) X 1.5m ( H )
Weight :Approx. 250 Kg
SERVICE REQUIRED :
440 v Ac Supply 50 Hz
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual
OPTIONAL FACILITY: Data logging Facility

Get More Details:- 5- INDIRECT AIR CONDITIONING CYCLE

WINDOW CONDITIONING CYCLE TEST RIG

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To study all components used in Air Conditioning system.
2. To study the Vapor compression Refrigeration cycle.
3. To study the cooling, humidification,& dehumidification process.
4. To determine the Refrigeration Effect, Work Input, Actual C.O.P.,Carnot C.O.P., Theoretical C.O.P., Relative C.O.P., Ton ofRefrigeration, and Plant Efficiency.
TECHNICAL DESCRIPTION :
The equipment consists of a hermetically sealed compressor, air cooled condenser, blower unit to force air through a duct mounted on frame, an evaporator adopted in the duct, heaters of suitable capacity are clamped in the duct.
The power to the heater can be controlled & the air is warmed while it passes over the heater. Rotameter is used in the regeneration circuit which measures the flow of refrigerant (R-134a). The mass flow rate in the duct can be varied by arrangement provided on the blower unit. There is arrangement provided on the blower unit. There is an arrangement for humidification achieved by introducing steam in the duct. The relative humidity of air at inlet & outlet can be measured
by a dry/wet bulb thermometer.
An expansion valve is provided in the circuit for throttling the gas from HP to LP.
There are two gauges for measurement of high & low pressure. Four
thermocouples are placed to measure the temperature of gas at the evaporator &
condenser, with help of digital temperature indicator. HP/LP cut out is provided
for the safety of compressor. The duct is insulated from out side to avoid the
heat loss.
The control panel consists of switches starter, voltmeter ammeter etc. The
measurement of power consumption of compressor by using energymeter.
The refrigeration circuit & duct are mounted on a fabricated frame. The blower
driven by motor is mounted on separate frame.
DIMENSIONS AND WEIGHT :
Size :2 m.(L)x 1.5 m(W) X 1.5m ( H )
Weight :Approx. 150 Kg
SERVICE REQUIRED :
440 v Ac Supply 50 Hz
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual
OPTIONAL FACILITY: Data logging Facility

Get More Details:- 6- WINDOW AIR CONDITIONING CYCLE

EXPERIMENTAL BOTTLE COOLER

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To study all components used in refrigeration system.
2. To study the Vapor compression Refrigeration cycle.
3. To determine the Refrigeration Effect, Work Input, Actual C.O.P., Carnot
C.O.P., Theoretical C.O.P., Relative C.O.P., Ton of Refrigeration, and
Plant Efficiency.
TECHNICAL DESCRIPTION :
The equipment consist of hermatically sealed compressor, condenser , expansion device and evaporator.The high pressure and high temperature compressed gas is passed through the air cooled condenser where its temperature drops down and it will come in liquid phase . The flow rate of liquid phase gas is measured by using rotameter, goes to expansion device where its temperature drops down. From expansion device gas goes to evaporator. From evaporator it will come to compressor and refrigeration cycle is completed.Temperature is measure across condenser and evaporator inlet and outlet respectively.compressor suction and discharge side pressure is also measured.The panel consists of switches, energymeter, pressure gauges, HP/LP cutout , Thermostat.

DIMENSIONS AND WEIGHT :
Size :1.5 m.(L)x 1 m(W) X 1.5m ( H )
Weight :Approx. 120 Kg
SERVICE REQUIRED :
230 v Ac Supply 50 Hz
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual
OPTIONAL FACILITY: Data logging Facility

Get More Details:- 9- EXPERIMENTAL BOTTLE COOLER

WATER CHILLING PLANT

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To study all components used in Air Conditioning system.
2. To study the Vapor compression Refrigeration cycle.
3. To determine the Refrigeration Effect, Work Input, Actual C.O.P.,Carnot C.O.P., Theoretical C.O.P., Relative C.O.P., Ton ofRefrigeration, and Plant Efficiency.
TECHNICAL DESCRIPTION :
The equipment consist of hermatically sealed compressor, condenser , expansion device and evaporator.The high pressure and high temperature compressed gas is passed through the air cooled condenser where its temperature drops down and it will come in liquid phase . The flow rate of liquid phase gas is measured by using rotameter, goes to expansion device where its temperature drops down. From expansion device gas goes to evaporator. From evaporator it will come to compressor and refrigeration cycle is completed.Temperature is measure across condenser and evaporator inlet and outlet respectively.compressor suction and discharge side pressure is also measured.The panel consists of switches, energymeter, pressure gauges, HP/LP cutout , Thermostat.

DIMENSIONS AND WEIGHT :
Size :2 m.(L)x 1.5 m(W) X 1.5m ( H )
Weight :Approx. 150 Kg
SERVICE REQUIRED :
230 v Ac Supply 50 Hz
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual
OPTIONAL FACILITY: Data logging Facility

Get More Details:- 7- WATER CHILLING PLANT