MASS TRANSFER WITH CHEMICAL REACTION
In this reactor contents are well stirred with the catalyst and uniform throughout. Thus exit stream from this reactor has the same composition as the fluid within the reactor. We can refer also mixed type reactor
RANGE OF EXPERIMENTS TO BE CARRIED OUT :
- To study mass transfer with chemical
- To calculate the rate constant k of given reaction
EXPERIMENTAL SETUP
Reactor : Material Stainless steel (SS) ,
Flow Measurement : 1 No. Pre calibrated Rota meter
Feed Tank : 2 No. of stainless steel feed tank
Feed Circulation : By Compressed Air
Pressure Regulator : 0 – 2 kgf / cm2
Pressure Gauge : Bourdon type0 – 2 kgf / cm2
Water Bath : Material SS , Double Wall ,
\ Insulated with glass Wool
Heater : Nichrome wire heater
Stirrer : 1 No.SS impeller and shaft coupled to
FHP Motor
Digital Temp Indicator : 0 – 200 0 C , Indicator cum Controller
Temp Sensor : CR/AL Type
Piping : SS, PVC
Setup Mounting : On sturdy MS stand with powder coated.
SPACE REQUIRED : 1.5 m. ( L) x 1.0 m (W) X 1.5 m (H).
SERVICE REQUIRED: Air Supply : @ 6 CFM, at 4 Kg /cm2
Power Supply : 230V, 50Hz, A. C.
CHEMICALS REQUIRED: NaOH, Ethanol, Phenolphthalein indicator,
Acetic acid, Distilled water.
WEIGHT : @ 55 Kg