SHELL & TUBE HEAT EXCHANGER

RANGE OF EXPERIMENTS TO BE CARRIED OUT :

  1. To determine Heat transfer rate of heating & cooling.
  2. To Calculate L.M.T.D.
  3. To determine Overall Heat Transfer Coefficient .
  4. To calculate Effectiveness of heat exchanger.
  5. The experiments can be conducted at various values of input & calculation can be made accordingly.

EXPERIMENTAL SETUP : 

  1. 1:2 pass Shell & tube Heat Exchanger with triangular pitch pipe fitting arrangements.
  2. Heating Arrangement : Heat Exchanger provided along with geysers.
  3. Rotameter for flow measurement of hot & cold water. Range : 0 – 11 LPM
  4. Set of thermocouples.

CONTROL PANEL : 

  1. 12 Channel Digital Temperature Indicator
  2. Switch for heaters.

SPACE REQUIRED : 

1.5 m.(L)x 1.0 m(W) table

SERVICE REQUIRED :

440 v Ac, 3 Phase Supply, 50 Hz

Water Supply @ 25 LPM

WEIGHT : @ 110 Kg