EVAPORATIVE COOLER

RANGE OF EXPERIMENTS TO BE CARRIED OUT: 1. To determine Heat transfer rate of heating & cooling. 2. To calculate Effectiveness of Evaporative cooler. 3. The experiments can be conducted at various values of input & calculation can be made accordingly. TECHNICAL DESCRIPTION : The equipment consist of duct in which evaporator coil circulated.2 nos of water sump tanks are provided for hot water and cold water. Hot water is circulated though evaporator coil and cold water sprinkles over evaporator coil.Exhaust fan is provided at the top of the evaporative duct.. temperature of water inlet and outlet are measured.flow rate of water is measured by using rotameter.entireunt fixed on a panel

DIMENSIONS AND WEIGHT :
Size :1.5 m.(L)x 1 m(W) X 1.5m ( H )
Weight :Approx. 90 Kg
SERVICE REQUIRED :
230 v Ac Supply 50 Hz
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual
OPTIONAL FACILITY: Data logging Facility

Get More Details:- 8- EVAPORATIVE COOLER

NATURAL COOLING TOWER

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To determine the cooling efficiency of Cooling Tower.
2. To calculate cooling rate.
TECHNICAL DESCRIPTION :
In a present cooling tower, series of fins arranged from top to bottom in such number that, water is sprayed/dropped at the top & it drips/falls down from to fin to the bottom fin. Fins provide maximum surface area to cool the water. Temperature at inlet & outlet can be measured with the help of sensors & digital temperature indicator. This is a typical Natural Cooling Tower & is widely used in small scale units. Its maintenance cost is also negligible.Flow Rate of water measured by using rotameter.
DIMENSIONS AND WEIGHT :
Size :1.5 m.(L)x 1.5 m(W) X 2m ( H )
Weight :Approx. 120 Kg
SERVICE REQUIRED : 440 v Ac Supply 50 Hz
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual
OPTIONAL FACILITY: Data logging Facility

Get More Details:- 10- NATURAL COOLING TOWER

FORCED DROUGHT COOLING TOWER

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To determine Volumetric mass transfer coefficient ( hD.a )
for air, water system in a cooling tower.
2. To study the temperature distribution along the height of the tower.
3. The experiments can be conducted at various flow rates
of Air & Water & calculation can be made accordingly.
4. Experiment can be conduct on both Induced &
Forced Draught condition.
5. To determine & compare the efficiency of the tower from Induced
& Forced Draught condition.
TECHNICAL DESCRIPTION :
In a present cooling tower , packed tower is provided, water is sprayed/dropped at the top & it drips/falls down from to fin to the bottom fin. packings provide maximum surface area to cool the water. Temperature at inlet & outlet can be measured with the help of sensors & digital temperature indicator. Flow Rate of water measured by using rotameter. Flow rate of air measured by using by manometer

DIMENSIONS AND WEIGHT :
Size :1.5 m.(L)x 1m(W) X 2m ( H )
Weight :Approx. 120 Kg
SERVICE REQUIRED :
440 v Ac Supply 50 Hz
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual
OPTIONAL FACILITY: Data logging Facility

Get More Details:- 11- FORCED DRAUGHT COOLING TOWER

WATER WATER HEAT PUMP

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To observe the working principal of heat pump cycle.
2. To determine Actual cooling C.O.P, Carnot C.O.P., Theoretical C.O.P.,Actual heating C.O.P., Relative C.O.P., Ton of Refrigeration Etc.
3. To determine the efficiency of the heat pump system.
4. Observe the working of refrigeration cycle also.
TECHNICAL DESCRIPTION :
Heat pumps are refrigeration systems in which the rejected heat is at least as important as the refrigeration effect. Heat pumps have been referred to as reverse-cycle refrigeration systems.
A heat pump, in the common thermodynamic sense, is a system in which refrigeration components ( compressors, condensers, evaporators, and expansion devices ) are used in such a manner as to take heat from a source ( air, water ground, etc. ) and give it up to a heat sink ( air, water, ground, etc.) that is at a higher temperature than the source. For many applications, the heat pump is designed in such a manner as to reverse the cooling and heating functions. This allows the use of the same equipment for both heating and cooling and individual structure. Other applications are designed to simultaneously utilize both the heating and cooling effects obtained from the cycle in the same structure.

DIMENSIONS AND WEIGHT :
Size :1.5 m.(L)x 1m(W) X 1.5m ( H )
Weight :Approx. 120 Kg
SERVICE REQUIRED :
230 v Ac Supply 50 Hz
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual
OPTIONAL FACILITY: Data logging Facility

Get More Details:- 12- WATER WATER HEAT PUMP

AIR WATER HEAT PUMP

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To observe the working principal of heat pump cycle.
2. To determine Actual cooling C.O.P, Carnot C.O.P., Theoretical C.O.P.,Actual heating C.O.P., Relative C.O.P., Ton of Refrigeration Etc.
3. To determine the efficiency of the heat pump system.
4. Observe the working of refrigeration cycle also.
TECHNICAL DESCRIPTION :
Heat pumps are refrigeration systems in which the rejected heat is at least as important as the refrigeration effect. Heat pumps have been referred to as reverse-cycle refrigeration systems.
A heat pump, in the common thermodynamic sense, is a system in which refrigeration components ( compressors, condensers, evaporators, and expansion devices ) are used in such a manner as to take heat from a source ( air, water ground, etc. ) and give it up to a heat sink ( air, water, ground, etc.) that is at a higher temperature than the source. For many applications, the heat pump is designed in such a manner as to reverse the cooling and heating functions. This allows the use of the same equipment for both heating and cooling and individual structure. Other applications are designed to simultaneously utilize both the heating and cooling effects obtained from the cycle in the same structure.

DIMENSIONS AND WEIGHT :
Size :1.5 m.(L)x 1m(W) X 1.5m ( H )
Weight :Approx. 120 Kg
SERVICE REQUIRED :
230 v Ac Supply 50 Hz
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual
OPTIONAL FACILITY: Data logging Facility

Get More Details:- 13- AIR WATER HEAT PUMP

CASCADE REFRIGERATION CYCLE TEST RIG

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To observe the working principal of Cascade System..
2. To determine Actual cooling C.O.P, Carnot C.O.P., Theoretical C.O.P., Actual heating C.O.P., Relative C.O.P., Ton of Refrigeration Etc.
3. To determine the efficiency of the system.
4. Observe the working of refrigeration cycle.
TECHNICAL DESCRIPTION :
A cascade refrigeration system can be considered to be equivalent to two independent vapor-compression systems linked together in such a way that the evaporator of the high-temperature system becomes the condenser of the low-temperature system. However, the working media of the two systems are separated from each other. This therefore, allows the use of different refrigerants working at different temperature ranges to achieve the desired effect, which would otherwise, need to be achieved by a single refrigerant working at a bigger operating pressure range. Thus, we can make use of suitable refrigerants at the higher and lower pressure ranges to derive maximum benefit.
DIMENSIONS AND WEIGHT :
Size :1.5 m.(L)x 1m(W) X 1.5m ( H )
Weight :Approx. 120 Kg
SERVICE REQUIRED : 230 v Ac Supply 50 Hz
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual
OPTIONAL FACILITY: Data logging Facility

Get More Details:- 14- CASCADE REFRIGERATION CYCLE

VORTEX TUBE APPARATUS

RANGE OF EXPERIMENTS TO BE CARRIED OUT: 1. Observe the Temperature separation phenomenon of vortex tube. 2. The experiments can be conducted at various of input pressure. TECHNICAL DESCRIPTION :
The Setup Consist Of Vortex tube with pressure gauge and control valve. Temperature indicator provided for measurement of inlet and outlet temperatures DIMENSIONS AND WEIGHT : Size :0.5 m.(L)x 0.5m(W) X 0.5m ( H ) Weight :Approx. 20 Kg SERVICE REQUIRED : 230 v Ac Supply 50 Hz SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual
OPTIONAL FACILITY: Data logging Facility

Get More Details:- 15- VORTEX TUBE APPARATUS

VAPOR ABSORPTION SYSTEM

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. Observe the Vapor absorption system.
2. The experiments can be conducted at various Heat Input.
TECHNICAL DESCRIPTION :
The Setup Consist Of absorber electrolux refrigerator. Heater arrangement is provided as loading device.Temperature is measured across condenser , evaporator. Power consumption is measure by using energy meter.
DIMENSIONS AND WEIGHT :
Size :1 m.(L)x 0.7m(W) X 1.5m ( H )
Weight :Approx. 50 Kg
SERVICE REQUIRED :
230 v Ac Supply 50 Hz
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual
OPTIONAL FACILITY: Data logging Facility

Get More Details:- 16- VAPOR ABSORPTION SYSTEM

AUTOMOBILE AIR CONDITIONING CYCLE TEST RIG

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To study all components used in Automobile Air Conditioning system.
2. To study the Vapor compression Refrigeration cycle.
3. To study the cooling, humidification,& dehumidification process.
4. To determine the Refrigeration Effect, Work Input, Actual C.O.P.,Carnot C.O.P., Theoretical C.O.P., Relative C.O.P., Ton ofRefrigeration, and Plant Efficiency.
TECHNICAL DESCRIPTION :
The equipment consists of a hermetically sealed compressor, air cooled condenser, blower unit to force air through a duct mounted on frame, an evaporator adopted in the duct, heaters of suitable capacity are clamped in the duct.
The power to the heater can be controlled & the air is warmed while it passes over the heater. Rotameter is used in the regeneration circuit which measures the flow of refrigerant (R-134a). The mass flow rate in the duct can be varied by arrangement provided on the blower unit.

There is arrangement provided on the blower unit. There is an arrangement for
humidification achieved by introducing steam in the duct. The relative humidity of
air at inlet & outlet can be measured by a dry/wet bulb thermometer. An
expansion valve is provided in the circuit for throttling the gas from HP to LP.
There are two gauges for measurement of high & low pressure. Four
thermocouples are placed to measure the temperature of gas at the evaporator &
condenser, with help of digital temperature indicator. HP/LP cut out is provided
for the safety of compressor. The duct is insulated from out side to avoid the
heat loss.
The control panel consists of switches starter, voltmeter ammeter etc. The
measurement of power consumption of compressor by using energymeter.
The refrigeration circuit & duct are mounted on a fabricated frame. The blower
driven by motor is mounted on separate frame.
DIMENSIONS AND WEIGHT :
Size :3 m.(L)x 1.5 m(W) X 1.5m ( H )
Weight :Approx. 160 Kg
SERVICE REQUIRED :
440 v Ac Supply 50 Hz
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual
OPTIONAL FACILITY: Data logging Facility

Get More Details:- 17- AUTOMOBILE AIR CONDITIONING CYCLE TEST RIG – Copy

CONDENSING UNIT WITH OPEN TYPE COMPRESSOR

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To study all components used in Condensing unit
2. To study the Vapor compression Refrigeration cycle.
4. To determine the Refrigeration Effect, Work Input, Actual C.O.P.,Carnot C.O.P., Theoretical C.O.P., Relative C.O.P., Ton ofRefrigeration, and Plant Efficiency.
TECHNICAL DESCRIPTION :
The equipment consist of hermatically sealed compressor, condenser , expansion device and evaporator.The high pressure and high temperature compressed gas is passed through the air cooled condenser where its temperature drops down and it will come in liquid phase . The flow rate of liquid phase gas is measured by using rotameter, goes to expansion device where its temperature drops down. From expansion device gas goes to evaporator. From evaporator it will come to compressor and refrigeration cycle is completed.Temperature is measure across condenser and evaporator inlet and outlet respectively.compressor suction and discharge side pressure is also measured.The panel consists of switches, energymeter, pressure gauges, HP/LP cutout , Thermostat.Water flow to the evaporator shell is measured by using rotameter
DIMENSIONS AND WEIGHT :
Size :1.2 m.(L)x 0.7 m(W) X 1.5m ( H ), Weight :Approx. 100 Kg
SERVICE REQUIRED : 440 v Ac Supply 50 Hz
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual
OPTIONAL FACILITY: Data logging Facility

Get More Details:- 18- CONDENSING UNIT WITH OPEN TYPE COMPRESSOR