CHARACTERISTICS OF CONTROL VALVE

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To Study and plot the characteristics of control valve.
TECHNICAL DESCRIPTION :
The setup consist of pneumatic actuated diaphragm control valve of two or three different types. An air filter regulator is used to provide constant air supply.A sump tank with centrifugal pump is provided.A measuring tank with level gauge is provided to measure the flow through the valve. By applying different pressure valve opening can be changed correspondingly flow rate through the valve is also changed.The valve opening and flow rate of water is used to plot the characteristics of control valve. The whole setup mounted on sturdy iron frame , powder coated with good color combination.
DIMENSIONS AND WEIGHT :
Size :0.75 m.(L)x 0.5m(W) X 1.2m ( H )
Weight :Approx. 75 Kg
SERVICE REQUIRED : Air Supply : @ 5 kg/cm2, Water : 100 ltr.
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual

Get More Details:- 11-CHARACTERISTICS OF CONTROL VALVE

TWO TANK INERACTING SYSTEM

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To Study the response of interacting system
2. To study the interacting system & find the parameter such as time constant and flow resistance of each tank.

TECHNICAL DESCRIPTION :
An interacting system is one in which working at each of its element depends
upon the state of the other elements. In the given experimental set up, two tanks
are connected to each other and hence called interacting system. The flow
Resistance ‘ R ‘ depends upon the difference between h1 & h2 & so system is
interacting . A sump tank with centrifugal pump is provided. A rotameter is used
to measure the flow the system. The whole setup mounted on sturdy iron frame ,
powder coated with good color combination.
DIMENSIONS AND WEIGHT :
Size :0.75 m.(L)x 0.75m(W) X 1.2m ( H )
Weight :Approx. 45 Kg
SERVICE REQUIRED :
Water : 100 ltr.
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual

Get More Details:- 12-TWO TANK INERACTING SYSTEM

TWO TANK NON INERACTING SYSTEM

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To Study the response of Non interacting system
2. To study the Non-interacting system & find the parameter such as time constant and flow resistance of each tank
.
TECHNICAL DESCRIPTION :
A non interacting system is that in which liquid level in the tank does not affect the liquid level in another tank. Since time constant of system is present on account of lag attened by system. A sump tank with centrifugal pump is provided. A rotameter is used to measure the flow the system. The whole setup mounted on sturdy iron frame , powder coated with good color combination.

DIMENSIONS AND WEIGHT :
Size :1.2 m.(L)x 0.75m(W) X 1.2m ( H )
Weight :Approx. 45 Kg
SERVICE REQUIRED :
Water : 100 ltr.
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual

Get More Details:- 13-TWO TANK NON INERACTING SYSTEM

CLOSED LOOP ELECTRONIC FLOW CONTROL SYSTEM

RANGE OF EXPERIMENTS TO BE CARRIED OUT: 1. To Study the closed loop electronic flow control system 2.To study the PID Controller. . TECHNICAL DESCRIPTION : The system comprises of Pneumatic actuated diaphragm control valve , wheel flow transmitter,I/P Convertor , PID controller and air filter regulator.The set point is set on the PID Controller. The output from the flow transmitter is given to the PID controller. The output from the PID controller is given to the I/P Covertor.The I/P convertor controls the flow of air to Pneumatic actuated diaphragm control valve which ultimately controls the flow of water through the valve. A sump tank with centrifugal pump is provided. A rotameter is used to measure the flow the system. The whole setup mounted on sturdy iron frame , powder coated with good color combination.

DIMENSIONS AND WEIGHT :
Size :1.2 m.(L)x 0.75m(W) X 1.2m ( H )
Weight :Approx. 75 Kg
SERVICE REQUIRED :
Water : 100 ltr.
Power Supply: 230 v AC Single Phase
Air Supply : @ 5 kg /cm2
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual

Get More Details:- 14-CLOSED LOOP ELECTRONIC FLOW CONTROL SYSTEM

CLOSED LOOP ELECTRONIC LEVEL CONTROL SYSTEM

RANGE OF EXPERIMENTS TO BE CARRIED OUT: 1. To Study the closed loop electronic Level control system 2.To study the PID Controller. . TECHNICAL DESCRIPTION : The system comprises of Pneumatic actuated diaphragm control valve , Level transmitter, I/P Convertor , PID controller and air filter regulator.The set point is set on the PID Controller. The output from the level transmitter is given to the PID controller. The output from the PID controller is given to the I/P Covertor.The I/P convertor controls the flow of air to Pneumatic actuated diaphragm control valve which ultimately controls the level of water in the tank. A sump tank with centrifugal pump is provided. A rotameter is used to measure the flow the system. The whole setup mounted on sturdy iron frame , powder coated with good color combination.

DIMENSIONS AND WEIGHT :
Size :1.2 m.(L)x 0.75m(W) X 1.2m ( H )
Weight :Approx. 75 Kg
SERVICE REQUIRED :
Water : 100 ltr.
Power Supply: 230 v AC Single Phase
Air Supply : @ 5 kg /cm2
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual

Get More Details:- 15-CLOSED LOOP ELECTRONIC LEVEL CONTROL SYSTEM

CLOSED LOOP ELECTRONIC PRESSURE CONTROL SYSTEM

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To Study the closed loop electronic Pressure control system
2.To study the PID Controller.
. TECHNICAL DESCRIPTION :
The system comprises of Pneumatic actuated diaphragm control valve , Pressure transmitter, I/P Convertor , PID controller and air filter regulator. The set point is set on the PID Controller. The output from the pressure transmitter is given to the PID controller. The output from the PID controller is given to the I/P Covertor.The I/P convertor controls the flow of air to Pneumatic actuated diaphragm control valve which ultimately controls the pressure of air in the tank. A suitable capacity compressor is provided for supply of air. The whole setup mounted on sturdy iron frame , powder coated with good color combination.
DIMENSIONS AND WEIGHT :
Size :1.2 m.(L)x 0.75m(W) X 1.2m ( H )
Weight :Approx. 75 Kg
SERVICE REQUIRED : Power Supply: 230 v AC Single Phase, Air Supply : @ 5 kg /cm2
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual

Get More Details:- 16-CLOSED LOOP ELECTRONIC PRESSURE CONTROL SYSTEM

CLOSED LOOP ELECTRONIC TEMPERATURE CONTROL SYSTEM

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To Study the closed loop electronic Temperature control system
2.To study the PID Controller.
. TECHNICAL DESCRIPTION :
The system comprises of Pneumatic actuated diaphragm control valve , Temperature transmitter, I/P Convertor , PID controller and air filter regulator. The set point is set on the PID Controller. The output from the Temperature transmitter is given to the PID controller. The output from the PID controller is given to the I/P Covertor.The I/P convertor controls the flow of air to Pneumatic actuated diaphragm control valve which ultimately controls the flow of water to maintain the required temperature in the system. An electric gyser is used to heat the water A rotameter is used to measure the flow of water. . A sump tank with centrifugal pump is provided. The whole setup mounted on sturdy iron frame , powder coated with good color combination.

DIMENSIONS AND WEIGHT :
Size :1.2 m.(L)x 0.75m(W) X 1.2m ( H )
Weight :Approx. 75 Kg
SERVICE REQUIRED :
Power Supply: 230 v AC Single Phase
Air Supply : @ 5 kg /cm2
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual

Get More Details:- 17-CLOSED LOOP ELECTRONIC TEMPERATURE CONTROL SYSTEM

CLOSED LOOP ELECTRONIC PH CONTROL SYSTEM

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To Study the closed loop electronic PH control system
2.To study the PID Controller.
. TECHNICAL DESCRIPTION :
The system comprises of Pneumatic actuated diaphragm control valve , PH transmitter, I/P Convertor , PID controller and air filter regulator. The set point is set on the PID Controller. The output from the PH transmitter is given to the PID controller. The output from the PID controller is given to the I/P Covertor.The I/P convertor controls the flow of air to Pneumatic actuated diaphragm control valve which ultimately controls the flow of reagents to maintain the required PH in the system.. A sump tank with centrifugal pump is provided. The whole setup mounted on sturdy iron frame , powder coated with good color combination.
DIMENSIONS AND WEIGHT :
Size :1.2 m.(L)x 0.75m(W) X 1.2m ( H )
Weight :Approx. 75 Kg
SERVICE REQUIRED : Power Supply: 230 v AC Single Phase, Air Supply : @ 5 kg /cm2
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual

Get More Details:- 18-CLOSED LOOP ELECTRONIC PH CONTROL SYSTEM

CLOSED LOOP ELECTRONIC MOISTURE CONTROL SYSTEM

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To Study the closed loop electronic Moisture control system
2.To study the PID Controller.
. TECHNICAL DESCRIPTION :
The system comprises of Pneumatic actuated diaphragm control valve , Moisture transmitter, I/P Convertor , PID controller and air filter regulator. The set point is set on the PID Controller. The output from the PH transmitter is given to the PID controller. The output from the PID controller is given to the I/P Covertor.The I/P convertor controls the flow of air to Pneumatic actuated diaphragm control valve which ultimately controls the flow of steam to maintain the required moisture in the system.. A suitable capacity boiler with heaters , pressure gauge and safety valve is provided. The whole setup mounted on sturdy iron frame , powder coated with good color combination.

DIMENSIONS AND WEIGHT :
Size :1.2 m.(L)x 0.75m(W) X 1.2m ( H )
Weight :Approx. 75 Kg
SERVICE REQUIRED :
Power Supply: 440 v AC Three Phase
Air Supply : Water 100 lpm
SCOPE OF DELIVERY:
1. Experimental Setup
2. Instructional Manual

Get More Details:- 19-CLOSED LOOP ELECTRONIC MOISTURE CONTROL SYSTEM

RESPONSE OF THE FIRST ORDER SYSTEM

RANGE OF EXPERIMENTS TO BE CARRIED OUT:
1. To Study the response of first order system
TECHNICAL DESCRIPTION :
Here Thermocouple and Thermometers are selected & used to measure the temperature.. The output signal from signal conditioning card is fed to next Microcontroller based Digital readout & its related circuit will be selected & actual measured temperature will be shown on Digital Read Out. An electric kettle is also provided for water bath.and also mercury glass thermometer.
DIMENSIONS AND WEIGHT :
Size :0.3 m.(L)x 0.3m(W) X 0.3m ( H )
Weight :Approx. 2 Kg
SERVICE REQUIRED :
POWER SUPPLY : 230V AC Single Phase

Get More Details:- 20-RESPONSE OF THE FIRST ORDER SYSTEM